Design, Development and Performance Evaluation of a UV Sensor-Based Hybrid Dual-Axis Solar Tracking System
Authors Ajay Oli
Abstract
Traditional fixed flat-plate PV installations lose significant output because they cannot maintain perpendicular alignment with the sun through the day and conventional sensor-based trackers that rely on light-dependent resistors (LDRs) suffer from two well-documented failure modes: saturation under strong sunlight and unreliable readings under cloud cover, since LDRs respond to the visible spectrum, which scatters more under those conditions. This project develops a dual-axis solar tracking system that uses UV sensors instead, since UV exposure at the surface is governed more by astronomical and atmospheric factors than by cloud scattering, so a UV sensor holds a usable, changing signal across a wider range of lighting conditions than an LDR does. The tracker runs a hybrid control strategy using four UV sensors arranged in a grid drive elevation and azimuth movement under normal daylight by comparing readings across sensor pairs. When readings fall outside a defined band, indicating sensor saturation or unreliably low light, control switches automatically to an open-loop mode that computes sun position from solar declination, equation of time, and altitude/azimuth formulas, holding position for 15-minute intervals before recalculating. The mechanical structure was sized for a full range of azimuth rotation and altitude adjustment, with motor torque, bearing life, and shaft fatigue calculated to withstand wind loading. An Arduino Mega with an L298N driver and a custom regulated power supply control a DC motor and linear actuator for the two axes. The system was field-tested over 60 days on the Western Regional Campus in Pokhara, Nepal, logging data every 10 seconds against a fixed-panel baseline. The hybrid tracker reached a peak efficiency of 10.1% against 9.43% for the fixed panel, delivered a 35.11% average increase in power output — exceeding 50% during morning and evening hours — and held tracking error to a maximum of 5.3°, compared with 8.9° for the astronomical-only mode running alone. These results support UV-sensor hybrid tracking as a workable alternative to LDR-based systems, particularly where lighting conditions vary through the day.
PERFORMANCE ANALYSIS OF DUAL-AXIS SOLAR TRACKING SYSTEM DUE TO TEMPERATURE VARIATION
Authors Ajay Oli
Abstract
In the growing market of energy demands and concerns over fossil fuel usage, solar energy can be the best renewable replacement that, if harnessed effectively, could become a significant advancement for the world. The harvesting efficiency of solar energy is significantly influenced by tracking systems and environmental factors, particularly temperature variations. This study presents a comparative analysis of dual-axis solar tracking systems, examining their performance under temperaturevariations using Light-Dependent Resistors (LDRs) and Ultraviolet (UV) sensors as input devices. The research was conducted using polycrystalline silicon solar panels with MG966R servo motors for precise positioning. Through experimentalevaluation, the UV sensor-based tracking system demonstrated superior performance with 9.54% efficiency, compared to 8.63% for the LDR system and 8.19% for the fixed system. The UV sensor exhibited enhanced tracking accuracy with a maximum error of 4.21 degrees, while LDR sensors showed limitations due to saturation issues under high light intensity, resulting in tracking errors of up to 8.66 degrees. The tracking system, particularly during non-peak hours, based in UV sensor achieved a 39.09% increase in overall power output compared to the fixed system, while the LDR system showed a 20.66% improvement. Efficiency of PV systems are highly dependent on temperature and the optimal performance of the PV system was found to be at 33.6◦C, with a maximum power output of 2.14 W, beyond which efficiency decreased by approximately 0.407% per ◦C in controlled conditions and 0.449% per ◦C in actual environments. Better sensor selection and temperature management can maximize photovoltaic efficiency, suggesting potential applications in regions with diverse environmental conditions. Integration of advanced sensors and the use of hybrid control algorithms can further enhance energy generation.
A Comprehensive Review on Production, Properties, and Sustainable Applications of Rice Husk Ash
Authors Ajay Oli
Abstract
Rice husk ash (RHA) is a silica-based byproduct of the combustion of rice husks, whereby its availability in the world is approximately more than 150 million tonnes/year, as a result of global rice production. This review critically summarizes the latest developments in the manufacture, properties, and sustainable use of RHA, and focuses on the quantitative relationship between processing conditions and the material performance. The subjected temperature of 500-700 °C, maintained under controlled combustion, invariably produces RHA having 80-95 % amorphous silica, and thus, this allows high pozzolanic reactivity. In cementitious systems, it has been repeatedly observed that optimum cement replacement rates of 10-20 % enhance compressive strength, durability, and chloride and sulfate attack resistance, along with reducing the related CO2 emission. Outside of construction, silica of purities above 99 % made by RHA has been used in plastics, adsorbents, and food filtration systems. Adsorption capacities have been reported to enable heavy metal (Pb, Cd, Zn, and Hg) removal during wastewater treatment, making RHA a low-cost environmental remediation material. Despite these benefits, timely adoption is still limited by a high degree of ash variability, the absence of standard production guidelines and protocols, difficulties in handling tiny aggregates and silt, and a limited regulatory direction. The review suggests future research steps, including variability of quality, standardization of processing, and techno-economic feasibility, as these are the main obstacles to industrial practice. New research directions, such as geopolymer binders, high-value nanosilica, and circular-economy-driven supply chains, are also noted in this study.
Finite Element Analysis of an Aircraft Landing Gear Lug Attachment: Comparison of Al 7075-T6 and Fe E400 Steel Under Drag and Vertical Loads
Authors Navaraj Parajuli, Ayan Shrestha
Abstract
When the landing gear is attached to the airframe bya lug, all of the ground reaction is transmitted through that lugduring the landing, taxiing and braking phases of an aircraft'soperation, and the failure of a lug has been a common cause oflanding gear failure investigations. The sizing and finite element(FE) analysis of a 150–200 seat transport aircraft fork–tongue–floor–beam lug attachment are presented. The gear reactionsare based on a two support idealisation of a static 35,250 kgaircraft, whereas the pin and rivet diameters are compared withshear allows. A 3D model developed in SolidWorks is exportedto ANSYS and analysed for drag load case and vertical loadcase, both the assembly is either aluminium alloy 7075-T6 or FeE400 steel. Both materials are lightly loaded (peak von Misesstress of 74 MPa and 62 MPa) under drag load. The maximumstresses under vertical load are 417 MPa (Al 7075-T6) and 373MPa (Fe E400), with the corresponding yield safety factors of1.21 and 1.07—these are below the ultimate factor of 1.5required by 14 CFR 25.303; the minimum fatigue lives predictedare zero cycles and 3,352 cycles, respectively. Steel has 2.8 timesthe weight for the same geometry, and is three times as stiff.Thus, the present geometry can be used for the drag case, butnot for the vertical case, and the results suggest a need for localreinforcement in the floor-beam flange area as opposed tomaterial changes.
Comparative Analysis of Five Cold-Plate Channel for Liquid Cooling of a Prismatic Lithium-ion Battery Cell
Authors bijaya sedhai
Abstract
"Five conventional cold-plate layouts – single serpentine (A1), double serpentine (A2) and I-, Z- and U-type parallel channels (A3, A4, A5) – are compared under identical conditions: a 148×100×6 mm aluminium plate with 4×4 mm channels, a 148×100×14 mm prismatic cell generating 20 W, and water at 25 °C. ANSYS Fluent simulations at 0.5–8 g/s are compared with hand calculations and a reduced-order model. The model and Fluent agree on the best (A1) and the worst (A5) layout, but the Fluent peak temperature is 1.7–3.1 K higher and the pressure loss differs from the friction-based model by a factor of 0.6 to 4.8. The single serpentine gives the lowest peak temperature and the best uniformity (spread 1.1–2.1 K) but needs 14–38 times more pumping power than the Z-type at the same flow. The Z-type is the best compromise: at 4 g/s it holds the plate below 30 °C(29.9 °C) with 89 Pa and 0.36 mW, 15 times less pumping power than the single serpentine needs for the same limit. Beyond 4 g/s, the peak temperature falls by only 1.0 K while the pumping power rises seven-fold. The U-type is the warmest and the leastuniform. At 3C (45 W) none of the layouts keeps the cell below 35 °C with 25 °C water, because most of the temperature rise is conduction through the cell.
Keywords: battery thermal management; liquid cold plate; serpentine channel; parallel channel; CFD; pressure drop; pumpingpower; mass flow rate"
Numerical Operational Modal Analysis of a Cantilever-Mounted Wind Turbine Blade under Variable Wind Excitation Using Frequency Domain Decomposition: Numerical Operational Modal Analysis of a Cantilever-Mounted Wind Turbine Blade under Variable Wind Excitation Using Frequency Domain Decomposition
Authors Toyanath Poudel
Abstract
Wind turbine blades are increasingly long and flexible, and their dynamic characteristics govern vibration, fatigue and structural integrity under continuously varying wind loads. Classical modal testing requires measured excitation, which is impractical for operating blades.This study assesses Frequency Domain Decomposition (FDD), an output-only Operational Modal Analysis technique, on a cantilever mounted wind turbine blade under variable wind excitation. A 1 m tapered aluminium blade was modelled in ANSYS Mechanical with a fixed root, and modal analysis gave six reference natural frequencies (104.35–1027.30 Hz). Transient analyses under wind-equivalent pressure at mean speeds of 2, 4, 6, 8 and 10 m s−1 (turbulence intensity 10.3 %) provided acceleration responses at five virtual sensors. The responses were processed in MATLAB using Welch cross-spectral estimation and singular value decomposition, with SSI-COV as a cross-check. Results were compared with the ANSYS reference using relative frequency error and the Modal Assurance Criterion (MAC). Response amplitude scaled with the square of wind speed, confirming linear behaviour. FDD identified modes 1 to 4 at every wind speed with frequency errors up to 3.43 % and MAC of at least 0.937, whereas modes 5 and 6 were not verified, owing to time-integration period elongation, the short record and limited sensor count.